Standard Tolerances


In the absence of tolerances specified on a customer drawing, MCE uses standard tolerances. These are listed below, along with what is the best tolerances we can hold, however, at a higher cost.

Standard MCE tolerances and best possible are as follows:

Feature

Units

Standard
Tolerance

Possible

Linear Dimension

Inches

0.5% or .005,
whichever is greater.

.000050"

Angular dimensions

Degrees

2

5 minutes

Perpendicularity

Degrees

2

5 minutes

Total Flux

Maxwell-Turns

5%

0.5%

Residual Flux Density

Gauss

5%

1.0%

Coercivity

Oersteds

Minimum as published

1000 Oe

Intrinsic Coercivity

Oersteds

Minimum as published

2000 Oe

Maximum Energy Product

MGOe

2 MGOe of Nominal

0.25 MGOe

As tolerances are tightened and greater demands are imposed on achieving a "perfect" part, costs begin to escalate rapidly. Good engineering practices require taking costs into consideration to produce a viable product for a particular application. Please give careful consideration as to what you really need so that we can provide a competitive product for your application.